Sök:

Sökresultat:

1574 Uppsatser om Waste water - Sida 1 av 105

Skillnader i vatten- och avloppshantering inom EU : En jämförelse mellan Slovakien och Sverige

The management of water resources and Waste water varies between the countries of the EU. For many years, a large part of the water in Europe has been contaminated by, among other things, insufficiently treated Waste water and emissions from agriculture. The EU Water Framework Directive 2000/60/EC and the Urban Waste water Directive 91/271/EEC are intended to harmonize fresh-water management and Waste water management within the whole EU, aiming at safeguarding drinking water of good quality and a high quality of all water within the EU today and in the future. There are however some problems concerning the waste-water directive. One problem is the huge investment needed in Slovakia to fulfil the demands of the waste-water directive for waste-water management in larger communities (with more than 2000 inhabitants).

Fällning av kisel från avloppsvatten vid Hellisheidarvirkjun - experimentell studie

This report is about the experiments with mixing of the separated water and the vacuum pump seal water at Hellisheiði power plant. This is done to prevent silica scaling and clogging in pipes and reinjection wells as well as eliminating vacuum pump seal water from the plant. The experiments were done in four stages: the first stage comprised of tests with different flows of separated water at 70°C, the second stage was carried out by mixing the separated water at 70°C and the seal water with different amounts of the seal water, the third and the fourth stages were like the first and second but with the separated water at 120°C. The results show that this method is good if the mixture is around 50/50 separated water and seal water, to control the silica scaling in the separated water and to be able to reinject the seal water with the separated water. This does not eliminate the silica scaling in all of the separated water because the amount of separated water is much more than the amount of seal water that comes from the plant. .

Undersökning av miljöstatusen i Gothemsån / Dalhem i anslutning till utsläpp av lakvatten från sopdeponi i Roma 2010

In October 2010 it was discovered that leach water had been released from a waste deposit directly into a ditch during a period from March until October 2010. The river Dalhemsån runs close to the waste deposit, just about 10 meters from the ditch. By studying the benthic fauna it was discovered that the environmental status of Dalhemsån is bad in this part of the river, but the discharges of leachate from the waste deposit does not seem to have deteriorated the water further since May 2010..

Spillvärmeåtervinning ur kylvattensystemet ismältverket på Sapa Profiler AB i Sjunnen

The smelting process at Sapa Profiler AB in Sjunnen generates large quantities of waste heat which is absorbed by the cooling water when the aluminum is cooled down. This paper is the result of a Master?s Degree Project aiming to present the conditions for recycling the waste heat. The cooling water absorbs the heat from the aluminum at an average rate of 600 kW and the paper shows that it can be used to replace electrical power consumption for heating the production plant?s facilities.

Analys av energiförbrukning, Akzo Nobel Functional Chemicals AB

The main purpose of this project was to make a survey of the steam and electricity consumption at Akzo Nobel Functional Chemistry AB and give suggestions of how to minimize them. These three different areas were focused on. First to make a survey of all the most important consumers, second to find the electricity consumption of the air compressors and the amount of waste heat produced from them. The third area was to calculate a model of how much fresh water that is used during a cooling sequence in the water based heating/cooling system of the reactors and give a suggestion of a suitable reuse for this water.The main result is a total survey of the energy consumption in steam and electricity. The survey shows that the second largest group after drying is heating of ventilation which gives big potentials of reducing the total steam consumption if there is a way of being self supporting in ventilation heat.

Kan perfluorerade ämnen i kläder bidra till förhöjda halter i reningsverk?

Perfluorinated substances (PF) are environmental pollutants that are used to coat fibres of so called ?all weather clothes? to make them water resistant. PF are effectively spread through water. Waste water treatment plants (WWTPs) are a pollutant source of these substances. PF are poisonous to different kinds of organisms, and supposedly also to human beings, if concentrations are sufficiently high.Perfluorinated substances have been investigated at three Waste water treatment plants in Stockholm during the 2000?s.

Spillvärmeåtervinning

SAPA´s resource of waste heat is the basis for this thesis to investigate the possibility of energy assets in their cooling water and possible uses for it. The energy in the Waste water is greater than the current need which has three uses which are (1) heating the factory, (2) converting liquid propane to propane gas and (3) local domestic heating. The average energy load that is available is 1, 7 MW and the average temperature in the cooling water is 41°C. The total energy load at dimensioning out side temperature is approximately 1,6 MW for the three current uses. The temperature is currently too low to be used directly in the existing systems so an upgrade is needed.

Reducering av produktionstryck i A-linan : Förflyttning av produkt

In the production of pulp, paper and cardboard, a large amount of water is used daily. The water has to be purified in the internal purifying plant before it reaches the receiving body of water. In the biological purifying stage at the Stora Enso Skoghall mill, an aerated basin is used where the microorganisms, using oxygen, oxidize the organic material to carbon dioxide. The air is pumped from the bottom of the basin and the oxygen can then be transported from the air bubbles to the water through diffusion. The problem with aeration of Waste water from the forest industry is that wood residues, such as fatty acids, are making the transport of oxygen in water more difficult.

Utredning av potentiella hälsorisker i samband med slagg- och slaggvattenhantering vid Hedenverket, Karlstad

In this study potential health risks for employees in connection with handling of bottom ash and bottom ash water at a Municipal Waste Incineration (MWI) plant have been investigated. Air surrounding the bottom ash and the bottom ash water has been examined. MWI is one of the primary ways to manage solid household waste, and bottom ash is the main solid residue produced by the incineration process. Bottom ash constitutes about 15-20% of the original waste. The bottom ash is extinguished in a water bath (bottom ash water).The study was carried out in a MWI plant in Karlstad, Sweden.

Identifiering av deponerat material i en deponi samt metodikförslag för upprättande av vattenbalans.

Högbytorp is Ragn-Sells? largest waste facility and it is located north of Stockholm. There is an old landfill still in use, but at the end of this year it will be closed. The waste deposited on the landfill can, through decomposition, give rise to a large amount of methane gas, which is an energy rich gas that can be used for heat and electricity production. To receive a relatively large amount of gas, the decomposition requires a high moisture content in the waste.

Anaerob psykrofil behandling av hushållsavloppsvatten i UASB : Utvärdering av kapaciteten hos en två-stegs UASB-reaktor för behandling av hushållsavloppsvatten

Hammarby Sjöstad is a new district in southern Stockholm. A main objective with the Sjöstad project was to halve the environmental impact compared to other construction work. The environmental goals involve a halved water consumption rate, a local treatment of storm water and trials aiming to extract nutrients from the Waste water. Sjöstadsverket is an experimental treatment plant used for testing new treatment processes for domestic Waste water from Hammarby Sjöstad. The results are to be compared with the conventional process used at Henrikdals treatment plant today.

Energieffektivisering av aerbo reningsprocess : Tillsats av biprodukter i skogsindustriellt avloppsvatten

In the production of pulp, paper and cardboard, a large amount of water is used daily. The water has to be purified in the internal purifying plant before it reaches the receiving body of water. In the biological purifying stage at the Stora Enso Skoghall mill, an aerated basin is used where the microorganisms, using oxygen, oxidize the organic material to carbon dioxide. The air is pumped from the bottom of the basin and the oxygen can then be transported from the air bubbles to the water through diffusion. The problem with aeration of Waste water from the forest industry is that wood residues, such as fatty acids, are making the transport of oxygen in water more difficult.

Hållbar avfallshantering : Ur ett ekonomiskt- och miljöperspektiv

Economy and environment has for a long time been studied separately and seen as incompatible. With a growing society and increasing pressure on environmental issues the need of a new economy with the environment included is necessary. This study examine if European Union´s picture of the waste hierarchy match the reality. Since the purpose with the waste hierarchy is to benefit environmental and economy. A survey was made over Käppalaförbundets waste from 2013, to see where the waste falls in the waste hierarchy.

Rening av avloppsvatten med anaerob membranbioreaktor och omvänd osmos

This master's theses was carried out on assignment from Stockholm Vatten AB as a part of a project developing new Waste water treatment techniques. The goal of the theisis has been to evaluate an anaerobic membrane bioreactor for treatment of Waste water from Hammarby Sjöstad. The bioreactor has not been heated and the main interest has been to study the gas production, power consumption and the reduction of organic matter and nutrients.The system has been completed with a reverse osmosis unit and a total of four batch runs have been made with good results. The use of reverse osmosis allows nutrient in the Waste water to be reintroduced into circulation as the reverse osmosis concentrate can be used as crop nutrient.The membrane unit is of VSEP ("Vibratory Shear Enhanced Processing") type and an extensive membrane test has been conducted. This so called L-test helped determine the most suitable type of membrane for the system to allow a higher ±ux and thus lower power consumption.

Energieffektivisering i ett reningsverk för skogsindustriellt avloppsvatten genom förfällning av extraktivämnen

Pulp- and papermills expend vast amounts of water in order to produce pulp, paper and cardboard. Hence, they alsocreate vast amounts of Waste water which has to be cleaned before it can be released into the receiving body of water. Insuch a wastewater treatment plant, tremendous amounts of energy are expended by the aeration in the biologicalcleaning process. This aeration is necessary to supply the microorganisms that shall decompose organic material withoxygen, which they need for their metabolism. The transfer of oxygen from the gas phase to the liquid phase isprimarily inhibited by surface-active substances in the Waste water like resin acids or fatty acids.

1 Nästa sida ->